MAXAIR® CAPR® systems are uniquely designed, NIOSH-approved, loose-fitting powered air-purifying respirators (PAPRs) that are setting standards for today and the future of respiratory and contact protection.
CAPR® systems provide workers with an unprecedented level of safety, comfort, convenience, and cost-effectiveness while helping protect against harmful aerosolized particulates.
Depending on the complete system selected—such as Cuff, Shroud, Hood, or Hard Hat configurations—MAXAIR® CAPR® systems can provide respiratory, contact, fluid, head, and/or eye-impact protection.
MAXAIR® is a leader in no-hose, integrated helmet design, and CAPR® systems are often referred to as “The No-Hose PAPRs.”
The integrated MAXAIR® Helmet eliminates the need for a cumbersome hose (breathing tube) and bulky waist- or back-mounted blower unit. Combined with its lightweight design (a typical system weighs approximately 2.26 pounds, with the Helmet and Face/Head Cover weighing approximately 1.76 pounds) MAXAIR® CAPR® systems provide greater mobility and comfort across a wide range of workplace settings.
The many complete system configurations available fall within three primary groups:
Cuff* Systems: Most cost-effective and easiest to don and doff
Shroud* Systems: Full 360° head and neck protection
Hood Systems: Full 360° head and neck protection with high fluid resistance (ASTM F1671)
*Optional relief from nuisance levels of organic vapors (N-OV) is available.
Yes, the up-to-date NIOSH approval numbers for MAXAIR® systems are all available on the NIOSH website.
No. All MAXAIR® Systems are positive-pressure, loose-fitting powered air-purifying respirators (PAPRs) that supply 6 to 9 cubic feet per minute (cfm) of airflow. OSHA does not require fit testing for positive-pressure, loose-fitting PAPRs.
OSHA does require annual fit testing for negative-pressure respirators, such as N95s, and for tight-fitting PAPRs, as both technologies require a tight seal against the face.
Additionally, OSHA requires all respirator users to complete a medical evaluation questionnaire before using any respirator and to undergo annual retraining on the respirators they use.
Yes. After decontamination and replacement of the comfort strips and single-use Face/Head Covers, MAXAIR® is ready for the next user.
MAXAIR® Helmets are designed to provide a universal fit through both circumferential and height adjustments built into the Helmet Liner Headband.
The universal Liner/Headband features a ratchet knob that adjusts for proper circumferential fit across a range of head sizes. Adjustable side straps allow for vertical positioning and proper helmet tilt, helping ensure comfort and clear visibility of the safety LEDs within the wearer’s upper peripheral vision.
The Safety LEDs are continuously illuminated and positioned within the user’s upper peripheral vision, allowing the user to remain focused on work activities, patient care, and other tasks without distraction. The LEDs automatically alert the user when it is time to exit the environment to recharge or replace the battery and/or check the status of the filter.
When illuminated, the yellow LED indicates a low-airflow condition. If it illuminates during use, the system is approaching a point where it may no longer be able to maintain the desired airflow. At this time, the filter should be checked to determine whether replacement is necessary.
The three green LEDs, together with the red LED, provide a general indication of the battery’s remaining charge:
Three green LEDs: Approximately 75%–100% charge remaining
Two green LEDs: Approximately 50%–75% charge remaining
One green LED: Approximately 25%–50% charge remaining. At this point, the user should plan to recharge or replace the battery at the next opportunity.
No green LEDs and one red LED: Approximately 0%–25% charge remaining. The user should replace or recharge the battery as soon as possible.
If both the red and yellow LEDs are illuminated, both the battery and filter should be checked and replaced as necessary.
In a typical healthcare environment, the yellow LED should rarely illuminate because these environments generally have lower particulate loading compared with many industrial applications.
The user can adjust the airflow switch, located on the posterior underside of the Helmet, between Low (6–7 cfm, 190 lpm), Medium (7–8 cfm, 215 lpm), and High (8–9 cfm, 240 lpm). This allows the user to match the airflow to a wide range of work environments and activity levels.
The MAXAIR® Air Flow Controller maintains each selected airflow setting at a constant level, even as the filter loads.
Note: All airflow values are approximate.
The integrated motor-fan, located at the top rear of the Helmet, draws ambient air through the filter. The filtered air is then channeled through the Helmet and flows downward between the lens and the user. This provides resistance-free breathing, helps prevent lens fogging, exhausts exhaled CO₂, and delivers a cooling effect for greater user comfort.
MAXAIR® CAPR® systems can be configured with appropriate face/head covers to provide protection against airborne particulates and varying degrees of contact/splash, fluid, and impact in a broad range of markets, including but not limited to the following.