MAXAIR® CAPR® systems are uniquely designed, NIOSH-approved, loose-fitting powered air-purifying respirators (PAPRs) that are setting standards for today and the future of respiratory and contact protection.
CAPR® systems provide workers with an unprecedented level of safety, comfort, convenience, and cost-effectiveness while helping protect against harmful aerosolized particulates.
Depending on the complete system selected—such as Cuff, Shroud, Hood, or Hard Hat configurations—MAXAIR® CAPR® systems can provide respiratory, contact, fluid, head, and/or eye-impact protection.
MAXAIR® is a leader in no-hose, integrated helmet design, and CAPR® systems are often referred to as “The No-Hose PAPRs.”
The integrated MAXAIR® Helmet eliminates the need for a cumbersome hose (breathing tube) and bulky waist- or back-mounted blower unit. Combined with its lightweight design (a typical system weighs approximately 2.26 pounds, with the Helmet and Face/Head Cover weighing approximately 1.76 pounds) MAXAIR® CAPR® systems provide greater mobility and comfort across a wide range of workplace settings.
The many complete system configurations available fall within three primary groups:
Cuff* Systems: Most cost-effective and easiest to don and doff
Shroud* Systems: Full 360° head and neck protection
Hood Systems: Full 360° head and neck protection with high fluid resistance (ASTM F1671)
*Optional relief from nuisance levels of organic vapors (N-OV) is available.
Yes, MAXAIR® Systems are now categorized under two NIOSH PAPR classes: PAPR HE and PAPR100. These classifications were established in April 2020 through the publication of “Approval Tests and Standards for Air-Purifying Particulate Respirators.”
Which Class a PAPR is approved for by NIOSH is primarily determined by its filtering characteristics. See the FAQs section Filter Media, “What are the CAPR® Filter Configurations?”, for more information on MAXAIR® PAPR Classifications.
Yes, the up-to-date NIOSH approval numbers for MAXAIR® systems are all available on the NIOSH website.
No. All MAXAIR® Systems are positive-pressure, loose-fitting powered air-purifying respirators (PAPRs) that supply 6 to 9 cubic feet per minute (cfm) of airflow. OSHA does not require fit testing for positive-pressure, loose-fitting PAPRs.
OSHA does require annual fit testing for negative-pressure respirators, such as N95s, and for tight-fitting PAPRs, as both technologies require a tight seal against the face.
Additionally, OSHA requires all respirator users to complete a medical evaluation questionnaire before using any respirator and to undergo annual retraining on the respirators they use.
Currently, there are four MAXAIR® Base Systems to choose from, which serve as the foundation for the many different MAXAIR® CAPR® Complete Systems. (Refer to PB-CAPR-Base Systems.pdf in the Product Brochures section at https://maxair-systems.com/product-literatures.)
Each Base System consists of a Helmet, Battery, Battery Belt, and Charger.
Helmet choices include:
2081-03 for non-Hard Hat Complete Systems
2084-03 for use with PR Hoods
2083-03 for all Hard Hat Complete Systems
Battery choices include:
2500-36TSC, typically 8–10 hours per full charge
2500-37TSC, typically 12–15 hours per full charge
Belt: 2000-76
Charger: 2600-02
To configure a MAXAIR® Complete System, a Head and Face Cover and the noted Base System peripherals must be included with the selected Base System. More detailed graphical descriptions of the many available Complete System options are provided on the MAXAIR® website.
MAXAIR® Helmets are designed to provide a universal fit through both circumferential and height adjustments built into the Helmet Liner Headband.
The universal Liner/Headband features a ratchet knob that adjusts for proper circumferential fit across a range of head sizes. Adjustable side straps allow for vertical positioning and proper helmet tilt, helping ensure comfort and clear visibility of the safety LEDs within the wearer’s upper peripheral vision.
Yes. After decontamination and replacement of the comfort strips and single-use Face/Head Covers, MAXAIR® is ready for the next user.
MAXAIR® CAPR® systems can be configured with appropriate face/head covers to provide protection against airborne particulates and varying degrees of contact/splash, fluid, and impact in a broad range of markets, including but not limited to the following.
Yes. The audio quality is optimum with our cuff configurations.
For general cleaning of MAXAIR® Helmets, Batteries, Chargers, Liners, Helmet Covers, and Power Cords, we recommend using a clean, damp cloth with a mild, skin-friendly soap.
For high-level cleaning, MAXAIR® recommends two alternatives:
PDI Super Sani-Cloth® Germicidal Disposable Wipe, Q55172
Clorox Healthcare® Hydrogen Peroxide Cleaner Disinfectant, CLO30825
All MAXAIR® Face/Head Covers are single-use items and are not designed for cleaning or reuse.
MAXAIR® Filters should be discarded as contaminated waste if the Helmet’s yellow LED remains illuminated for more than approximately 10 seconds after the Helmet is powered on. Filters should also be discarded whenever they are soiled, visibly damaged, or contaminated with body fluids.
MAXAIR® noise levels are lower than those of conventional PAPRs, with an average sound level typically below 62 dB.
Yes, all configurations fit users with facial hair, that wear glasses, and nearly all head sizes and shapes.
No additional attachments are needed.
Assembly, disassembly, donning, and doffing instructions for all MAXAIR® System configurations can be found in the MAXAIR® UIMs (User Instruction Manuals) supplied with each MAXAIR® Helmet, as well as in the Item UIMs included in each box of Face/Head Covers.
The integrated motor-fan, located at the top rear of the Helmet, draws ambient air through the filter. The filtered air is then channeled through the Helmet and flows downward between the lens and the user. This provides resistance-free breathing, helps prevent lens fogging, exhausts exhaled CO₂, and delivers a cooling effect for greater user comfort.
The user can adjust the airflow switch, located on the posterior underside of the Helmet, between Low (6–7 cfm, 190 lpm), Medium (7–8 cfm, 215 lpm), and High (8–9 cfm, 240 lpm). This allows the user to match the airflow to a wide range of work environments and activity levels.
The MAXAIR® Air Flow Controller maintains each selected airflow setting at a constant level, even as the filter loads.
Note: All airflow values are approximate.
The Safety LEDs are continuously illuminated and positioned within the user’s upper peripheral vision, allowing the user to remain focused on work activities, patient care, and other tasks without distraction. The LEDs automatically alert the user when it is time to exit the environment to recharge or replace the battery and/or check the status of the filter.
When illuminated, the yellow LED indicates a low-airflow condition. If it illuminates during use, the system is approaching a point where it may no longer be able to maintain the desired airflow. At this time, the filter should be checked to determine whether replacement is necessary.
The three green LEDs, together with the red LED, provide a general indication of the battery’s remaining charge:
Three green LEDs: Approximately 75%–100% charge remaining
Two green LEDs: Approximately 50%–75% charge remaining
One green LED: Approximately 25%–50% charge remaining. At this point, the user should plan to recharge or replace the battery at the next opportunity.
No green LEDs and one red LED: Approximately 0%–25% charge remaining. The user should replace or recharge the battery as soon as possible.
If both the red and yellow LEDs are illuminated, both the battery and filter should be checked and replaced as necessary.
In a typical healthcare environment, the yellow LED should rarely illuminate because these environments generally have lower particulate loading compared with many industrial applications.
Yes. All MAXAIR® System configurations include a filter cover that protects the filter or filter cartridge.
For Cuff and Shroud Systems, the filter or filter cartridge is covered by the 2061-08 Filter Cover Cap (FCC) or the 2061-04A Hard Hat when head-impact protection is required. For Hood Systems, the Hood Filter may be protected by the 2061-05 High Fluid Resistant Filter Cover Cap (HFR FCC).