Preferred Complete Systems For Healthcare Facility Environments

The Personal Protection Equipment needs for Healthcare Workers is as varied as it is extensive. 

From frequent Infection Control with infectious patients in Airborne Infection Isolation Rooms (AIIR), to special procedures as bronchoscopy, to emergency preparedness and pandemic critical times, there is an optimum CAPR Configuration.

CAPR focuses on the Health Care Worker and is designed for comfort and convenience to facilitate excellent user compliance with their RPP.

Preferred Complete Systems For Hospital Environments

The Personal Protection Equipment needs for Healthcare Workers is as varied as it is extensive. 

From frequent Infection Control with infectious patients in Airborne Infection Isolation (AII) rooms, to special procedures as bronchroscopy, to emergency preparedness and pandemic critical times, there is an optimum CAPR Configuration.

CAPR focuses on the Health Care Worker and is designed for comfort and convenience to facilitate excellent user compliance with their respiratory and contact protection PPE.

MAXAIR Cuff

Cuff

For situations requiring the most cost-effective balance between Safety, Comfort, and Convenience.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • Standard HE Filter
  • Filter Cover Cap
  • DLC Cuff – Full Face Cover (eyes, nose, mouth)

Safety with Convenience: NIOSH 99.97% HE Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - NO breathing tube, no waist mounted blower unit
Full Face Cover – NO need for separate Face Shields, bouffants, etc.

Affordable: Most economical full-coverage change-out between uses
More cost-effective than N95-based programs.

MAXAIR Shroud

Shroud

For situations where full 360° coverage and protection of face, head and neck is desired, and where reuse of filters protected by the Filter Cover Cap can reduce on-going cost-per-use.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • XP Filter
  • Filter Cover Cap
  • DLC Single Shroud with Level 41 materials

Safety with Convenience: 99.99%2 Filtration Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Affordable: Most economical full-coverage change-out between uses

1 ANSI/AMMI PB70:2020
2APF (1,000)

MAXAIR Hood

Hood, PH

When maximum body coverage, high fluid protection, and safety in doffing top the requirements list. A single piece, 360° full head to below-the-shoulders cover for routine use throughout the healthcare facility, particularly when filtered exhaust source control to protect the unprotected near the wearer is paramount.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • Filter integrated in the Hood
  • PB Style Single Hood
    • Front Materials below filter line: AAMI Level 41
    • Filter: AATCC 127 50 cm1
    • Back materials: AAMI Level 3 with >96% OPR (Source Control)1,2
    • No need for additional mask/N95 respirator2

Safety with Convenience: NIOSH 99.97% HE Efficiency; “NO FIT TESTING REQUIRED

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Safety with Affordability: Cost competitive full Hood includes New Filter with each changeout

1 ANSI/AAMI PB70:2020
2 Syntech Intl Technical Bulletin on OPR, P/N 04123045

MAXAIR HFR Hood

HFR FCC Hood, PB

For Ebola and other severe Pandemic Level situations that may require very high fluid resistance (360°) in addition to the highest protection against airborne particulates.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • Filter integrated in the Hood
  • PB Style Double Hood
    • Materials below filter line: AAMI Level 41
    • Filter: AATCC 127 50 cm1
    • HFR FCC provides a fluid impermeable cover over the entire Hood Filter

Safety with Convenience: 99.99%2 Filtration Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Safety – High Efficiency2, High APF2, High Fluid Resistance1

1 ANSI/AAMI PB70:2020
2 HIGH APF (1,000)

MAXAIR Cuff

Hard Hat

For Emergency Preparedness when emergency considerations include requiring respiratory, fluid, and impact protection as with pandemics, terrorist attacks, and natural disasters as tornadoes, earthquakes, explosions, etc.

Standard Complete System:

  • Base System:

        ◦ CAPR Hard Hat Helmet

        ◦ Li-Ion Standard Battery

        ◦ Standard Battery Belt

        ◦ Battery Charger

  • ANSI/ISEA Z98.1-2014 Type 1, Class G & C Hard Hat
  • High Fluid Resistant Single Shroud1
  • XP Filter2
  • Optional ANSI Z87.1 (Impact Lens, available)
  • DLC Shroud (Optional alternate for Cuff, available)

NIOSH Approved; “NO FIT TESTING REQUIRED”

Safety with Convenience: 99.99%2 Filtration Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Safety – High Efficiency2, High APF2, High Fluid Resistance1

1 Materials: Level 4, ANSI/AAMI PB70:2020
2 HIGH APF (1,000)

Protect yourself with the best Powered Air Purifying Respirators on the market.
Get a quote today!

Maxair PPE equipment

For nearly 20 years, MAXAIR Systems is providing creative solutions to meet the needs wherever personal respiratory and contact concerns demand the highest quality of safety and comfort to the user. 

Contact Information