Preferred Complete Systems For Surgery/OSC/ASC Environments

The Personal Protection Equipment needs for Surgery/OR is as varied as it is extensive. 

From frequent Infection Control with infectious patients in Airborne Infection Isolation Rooms (AIIR), to special procedures as bronchoscopy, to emergency preparedness and pandemic critical times, there is an optimum CAPR Configuration.

CAPR focuses on the Health Care Worker and is designed for comfort and convenience to facilitate excellent user compliance with their RPP.

Preferred Complete Systems For Hospital Environments

The Personal Protection Equipment needs for Healthcare Workers is as varied as it is extensive. 

From frequent Infection Control with infectious patients in Airborne Infection Isolation (AII) rooms, to special procedures as bronchroscopy, to emergency preparedness and pandemic critical times, there is an optimum CAPR Configuration.

CAPR focuses on the Health Care Worker and is designed for comfort and convenience to facilitate excellent user compliance with their respiratory and contact protection PPE.

MAXAIR PRS Hood

Hood, PRS

For sterile applications requiring maximum body coverage, high fluid protection, and safety in doffing. A single piece, 360° full head to below-the-shoulders cover for all situations requiring sterile technique, particularly when filtered exhaust source control to protect the unprotected near the wearer is paramount.

Standard Complete System:

  • Base System:

    • CAPR PR Helmet

    • Li-Ion Standard Battery

    • Standard Battery Belt

    • Battery Charger

  • Filter integrated in the Hood

  • PRS1 Style Single Hood

    • Front Materials below filter line: AAMI Level 42

    • Filter: AATCC 127 50 cm2

    • Back materials: AAMI Level 3 with >96% OPR (Source Control)2,3

    • No need for additional mask/N95 respirator3

Safety with Convenience: NIOSH 99.99%4 HE Efficiency; “NO FIT TESTING REQUIRED

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Safety with Affordability: Cost competitive full Hood includes New Filter with each changeout

1Requires CAPR PR Helmet, 2084-04
2 ANSI/AAMI PB70:2020
3 Syntech Intl Technical Bulletin on OPR, P/N 04123045
4HIGH APF (1000)

MAXAIR PR Hood

Hood, PR

For applications requiring maximum body coverage, high fluid protection, and safety in doffing. A single piece, 360° full head to below-the-shoulders cover for all situations, particularly when filtered exhaust source control to protect the unprotected near the wearer is paramount, and where sterile head covering is not required.

Standard Complete System:

  • Base System:
    • CAPR PR Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • Filter integrated in the Hood
  • PR1 Style Single Hood
    • Front Materials below filter line: AAMI Level 42
    • Filter: AATCC 127 50 cm2
    • Back materials: AAMI Level 3 with >96% OPR (Source Control)2,3
    • No need for additional mask/N95 respirator3

Safety with Convenience: NIOSH 99.97% HE Efficiency; “NO FIT TESTING REQUIRED

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Safety with Affordability: Cost competitive full Hood includes New Filter with each changeout

1 Requires CAPR PR Helmet, 2084-04
1 ANSI/AAMI PB70:2020
2 Syntech Intl Technical Bulletin on OPR, P/N 04123045

MAXAIR Shroud

Shroud

For non-sterile applications requiring maximum body coverage, high respiratory protection, and high fluid protection, with a more cost-effective solution. A single piece, 360° full head to below the-shoulders cover where reuse of filters protected by the Filter Cover Cap can reduce on-going cost-per-use.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • XP Filter1
  • Filter Cover Cap
  • DLC Single Shroud with Level 41 outer shroud materials

Safety with Convenience: 99.99%1 Filtration Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - No breathing tube, no waist mounted blower unit

Affordable: Most economical full-coverage change-out between uses

1APF (1,000)
2 ANSI/AMMI PB70:2020

MAXAIR Cuff

Cuff

For nonsterile situations where the most cost-effective full face high protection factor respiratory and contact protection is needed.

Standard Complete System:

  • Base System:
    • CAPR Standard Helmet
    • Li-Ion Standard Battery
    • Standard Battery Belt
    • Battery Charger
  • Standard HE Filter
  • Filter Cover Cap
  • DLC Cuff – Full Face Cover (eyes, nose, mouth)

Safety with Convenience: NIOSH 99.97% HE Efficiency; “NO FIT TESTING REQUIRED”

Safety with Comfort: Integrated Helmet - NO breathing tube, no waist mounted blower unit
Full Face Cover – NO need for separate Face Shields, bouffants, etc.

Affordable: Most economical full-coverage change-out between uses
More cost-effective than N95-based programs.

Maxair PPE equipment

For nearly 20 years, MAXAIR Systems is providing creative solutions to meet the needs wherever personal respiratory and contact concerns demand the highest quality of safety and comfort to the user. 

Contact Information